User's Manual
Priming
30 313875J
Priming
1. Place waste containers below both ratio check dis-
pense valves.
NOTE: Both ratio check dispense valves will be open
when dispensing in Prime Mode. Only one pump moves
but material may drip from the other ratio check dis-
pense valve when opened.
2. Verify RAM director valve is in the DOWN position
and air pressure is applied to the RAM.
3. Press repeatedly to select Prime Mode then
press to accept.
4. Check the dispense settings shown at the bottom of
the screen.
5. If desired, change the dispense settings.
a. Press to enter editing mode.
b. Use the left and right arrow keys to select the
item to change.
c. Use the numeric keypad to type the new value.
d. Press to accept the new value.
e. Press to exit editing mode.
6. Press to select the A (Red) side.
7. Press to begin dispensing A (Red) material.
8. Continue dispensing until clean, air-free material is
dispensed from both sides then press to stop
dispensing.
9. Press to select the B (Blue) side.
10. Press to begin dispensing B (Blue) material.
11. Continue dispensing until clean, air-free material is
dispensed from both sides then press to stop
dispensing.