User's Manual
Setup
26 313875J
11.If applicable, attach and adjust
drum low/empty sensor.
NOTE: An optional kit can be purchased to indicate
either when the drum is low or when it is empty.
a. Position ram at desired level (low or empty).
b. Attach low/empty sensor bracket (A) to mount-
ing bracket (B).
c. Attach the actuator (D) to the ram piston rod,
near the top, so it passes in front of the
sensor (E) at the correct level for drum low or
drum empty.
12.Install material drums. See Install
Drum procedure, page 29.
13.Perform Startup procedure,
page 28.
14.Perform ADM setup.
NOTE: All ADM setup items are located in the Setup
screens. See Appendix B - ADM Setup Screens Over-
view beginning on page 59 for more information.
See ADM Operation Overview on page 31 for help with
operating the ADM including how to modify settings.
a. Navigate to Advanced #1 screen then set gen-
eral system settings. See page 63.
b. Navigate to Advanced #2 screen then set units
of measure. See page 63.
c. Navigate to Advanced #3 screen then
enable/disable system features. See page 64.
d. Navigate to System #1 screen then define con-
trol mode, dispense mode, and pump informa-
tion. See page 61.
e. Navigate to System #2 screen then define dis-
pense valve details and other system settings.
See page 61.
f. Navigate to System #3 screen then define
labels, pressure imbalance, and flow meter
details. See page 62.
g. Navigate to Shots screen then define shots.
See page 59.
h. Navigate to Sequences screen then define
sequences. See page 60.
i. If desired, navigate to Maintenance screen
then reset counters. See page 62.
15.Perform System Setup and Cali-
bration procedure on page 34.
A
B
D
E
ti10916a