User's Manual
Component Identification
14 313875J
Integrated Air Controls
The integrated air controls include:
• Main air slider valve (CA): turns air on and off to
the ram system. When closed, the valve relieves
pressure downstream.
• Ram air regulator (CB): controls ram up and down
pressure and blowoff pressure.
• Ram director valve (CC): controls ram direction.
• Exhaust port with muffler (CD)
• Blowoff button (CE): turns air on and off to push
the platen out of an empty drum.
Circuit Breakers
Most circuit breakers are located inside the power distri-
bution box. The main block of circuit breakers in the
power distribution box is shown below, with detailed
information in the following table. See the power distri-
bution box manual for more information.
F
IG. 4: Component Identification
CA
CE
CB
CC
CD
Ref.
Size
Component
230V/
3 phase
400V/
3 phase
CB1 30A 63A Motor Control Module
CB5 5A 5A Miscellaneous
CB6 5A 5A Miscellaneous
CB10 30A 63A Motor Control Module
CB1 CB5 CB10CB6