User's Manual

Repair
16 313874E
Adjust Motor Control Module Selector
Switch
The Motor Control Module uses an 8-position selector
switch (S) to set system maximum working pressure.
See FIG.5.
The system must be configured to have a maximum
working pressure of 2000 psi (13.8 MPa, 138 bar). Set
the selector switch according to the following table.
The selector switch position will be properly set at the
factory for new systems. When a motor control module
is replaced, the selector switch must be set to the cor-
rect setting by the user prior to initial startup.
To set the Motor Control Module selector switch:
1. Turn machine power off.
2. Remove the access cover (D). See FIG.5.
3. Set the selector switch (S).
4. Install access cover (D).
Install Motor Control Module
This procedure starts assuming that the old Motor Con-
trol Module is removed from the machine. See Remove
Motor Control Module procedure, see page 15.
See FIG. 4 on page 14.
1. Perform Adjust Motor Control Module Selector
Switch procedure on page 16.
2. Slide the Motor Control Module into the slot.
3. Attach the cable on the bottom of the Motor Control
Module.
4. Install the six screws (429) securing Motor Control
Module in place.
5. Install electrical cables on left and right sides of the
Motor Control Module.
6. Install four screws (432) connecting fan to Motor
and Motor Control Module. Install fan and mounting
plate.
7. Install Hydraulic Power Pack Shroud, see proce-
dure on page 15.
NOTICE
If the Motor Control Module is replaced, the selec-
tor switch must be set prior to initial star tup of the
Motor Control Module or damage may occur.
MCM Switch Position
B (Blue) 1
A (Red) 2
Do not install components rated to less than the
maximum working pressure. Doing so may lead to
overpressurization and ruptured components.
High-pressure fluid from ruptured components will
pierce skin. This may look like just a cut, but it is a
serious injury that can result in amputation. Get
immediate surgical treatment.
FIG.5
NOTICE
Motor Control Module selector switch position must
be set prior to startup of Motor Control Module or
damage may occur.
S
257396_3b9905_04b
D