User's Manual

Repair
12 313874E
Dura-Flo Lower Removal
NOTE: This procedure details how to remove the
Dura-Flo Lower. Rebuild information is in the Dura-Flo
Lower manual.
See FIG. 3 for part references.
1. Perform Shutdown and Pressure Relief Proce-
dure procedures. See operation manual for proce-
dures.
2. Loosen the coupling nut (603) to disconnect the
hydraulic vertical actuator and pump rods.
3. Use a large adjustable wrench to remove the large
inlet feed fittings at the base of the Dura-Flo Lowers.
4. Remove three screws (608).
5. Remove Dura-Flo Lower.
6. See Dura-Flo Lower manual for rebuild information.
NOTE: Install Dura-Flow Lower in reverse order. See
notes in the applicable parts illustrations for torque and
other specifications.
FIG.3
601
606
605
603
602
607
608
621618619620622
613
604
Isometric View
Torque 50-60 ft-lb (68-81 N•m).
Torque 145-155 ft-lb (196-210 N•m).
Apply thread lubricant.
Apply thread sealant.
1
2
3
4
1
3
2
4
1
3
2
_1c
ti17669a
604
3
623