User's Manual

313759A 9
Nipple Installation Instructions
A M8x1 connection for fitting + sleeve
B Copper Washer
C M10 x 1 or M12 x 1 straight fitting for dosers
1. (If adding nipple to casting with red or white plug, or
replacing an existing nipple) Relieve pressure,
page 7.
2. Carefully remove cap.
NOTE: Due to spring located under cap, cap will be
under pressure.
3. Thread nipple into fitting. Torque to 13 to 17. 7 in-lbs
(1.46 to 1.99 N.m).
NOTE: For a #1 nipple only, piston must also be
removed. Then install piston from #1 nipple followed by
nipple. Torque to specification in step 3.
FIG. 4
A
BC