User's Manual
8 313759A
Pressure Relief Procedure
The equipment may be pressurized or may become
pressurized by an automatic lubrication cycle initiated by
a lubrication controller such as a timer.
1. Disconnect power to the timer.
2. Consult your pump manual for any additional pres-
sure relief instructions related to your pump modu-
lal.
Single Line Circuit (FIG. 1)
A Doser
B Pressure Filter
C Lubrication Unit
Single Point to Manifold Assembly
Instructions
1. Install gasket washer between piston distributor and
manifold.
2. Thread in manifold. Torque to 17 in.-lbs (2 N.m).
Direct to Bearing Option (FIG. 2)
Used in centralized, single line lubrication systems,
injecting lubricant from an intermittent pump system.
The piston distributor is mounted directly on the grease
point.
ADoser
B Pressure Filter
C Lubrication Unit
Assembly Options
Insert into the previously machined housing.
FIG. 1
AA
A
B
C
F
IG. 2
F
IG. 3
B
A
A
C