User's Manual
Installation
8 313599P
Fluid Flow Downward
If this method is used, install the check valve at the
meter outlet. This provides back pressure in the meter,
ensuring that the fluid flow remains smooth and even.
See F
IG. 2.
Horizontal Mounting
The meter transmitter must be either above or below the
fluid line to ensure that solids do not collect and air does
not become trapped in metering tube. See F
IG. 3.
Fluid Line Connection
Connect the fluid supply line to the meter inlet.
Connect the 5 ft (1.52 m) fluid hose (10) from the meter
outlet to the appropriate component A or B dispense
valve. See F
IG. 6 on page 10.
Grounding
Flow Meter Sensor
Ground the flow meter sensor by connecting the signal
cable ground wire as shown in F
IG. 6 and FIG. 7 on
pages 10 and 11, respectively.
Have a qualified electrician check resistance between
the flow meter sensor and a true earth ground. If resis-
tance is greater than 1 ohm, a different ground site may
be required. Do not operate until the problem is cor-
rected.
Meter Fluid Manifold
Ground the meter fluid housing by connecting the power
cable ground wire as shown in F
IG. 5 on page 9.
Connect conductive fluid hoses to the meter inlet and
outlet.
F
IG. 2. Fluid Flow Downward
F
IG. 3. Horizontal Mounting
FlowFlow
check valve
TI4937a
Flow Flow
transmitter
check valve
Check hoses, tubes, and couplings daily. Tighten con-
nections before operating. Replace worn or damaged
parts immediately.
Your system must be grounded. Never use the flow
meter with an electrostatic gun isolation system.