User's Manual

Technical Data
313599P 29
Technical Data
* When used with ProMix 2KS/2KE/3KS and ProControl 1KS systems. When used with Informer or ProControl 1KE, the maxi-
mum temperature is
200° F (93° C). See Endress+Hauser meter manual for additional information.
** Promass
®
and Cubemass
®
are registered trademarks of Endress+Hauser.
Part No. 15V806 and 258151 Coriolis Meter Kits
U.S. Metric
Maximum Fluid Working Pressure 2300 psi 16 MPa, 160 bar
Fluid wetted parts (meter) 1.4539/904L stainless steel alloy C-22 2.4602/N 06022
Fluid wetted parts (hose and fittings) 303, 304 stainless steel, PTFE
Fluid Temperature Range* 41-122° F 5-50° C
Maximum Ambient Temperature* 122° F 50° C
Fluid Inlet/Outlet 4-VCO-4 Face Seal
Power and Signal Cable Entry 1/2 npt strain relief
Resolution settable 0.020-0.150 cc/pulse
Accuracy see Endress+Hauser manual
Supply Voltage 24 Vdc
Weight (meter only)
Part No. 15V806
Part No. 258151
33 lb
29 lb
15 kg
13 kg
Part No. 24M260, 24M261, and 24N525 Coriolis Meter Kits
U.S. Metric
Maximum Fluid Working Pressure 2300 psi 16 MPa, 160 bar
Fluid wetted parts (meter) 1.4539/904L stainless steel alloy C-22 2.4602/N 06022
Fluid wetted parts (hose and fittings) 303, 304 stainless steel, PTFE
Fluid Temperature Range* 41-122° F 5-50° C
Maximum Ambient Temperature* 122° F 50° C
Fluid Inlet Fitting 1/4 nps
Fluid Outlet Fitting 1/4 npt
Power and Signal Cable Entry 1/2 npt strain relief
Resolution settable 0.020-0.150 cc/pulse
Accuracy see Endress+Hauser manual
Supply Voltage 24 Vdc
Weight (meter only) 12.1 lb 5.5 kg