Cubemass Meter Minimum Required Setup Table
The following are the recommended settings for using the Cubemass meter with the proportioner. If a value is not
mentioned, use the default Endress+Hauser setting.
* When changing a value, use or keys to toggle through available selections. Use Enter key to select
and save each value. Only the value flashing can be selected; you may have to select and press for each
digit or unit to move to the next digit/unit.
Table 3: Cubemass Meter Values to use with Proportioner
Block Group
Function
Group Function Value*
Parameter
No.
Measured
Variables
System Units Configuration Unit Volume
Flow
cc/min 402
Unit Volume cc 403
User Interface Main Line Configuration Assign Volume Flow 2220
Additional Line Assign Totalizer 1 2400
Totalizer Totalizer 1 Configuration Assign Volume Flow 3000
Unit Totalizer No - default setting 3001
Outputs Current Output Configuration Assign Current
Output
Volume Flow 4000
Pulse/Fre-
quency Output
Configuration Mode of Oper-
ation
Pulse 4200
Pulse Volume Flow 4221
Pulse Value
(K-Factor)
0.020 cc/pulse for Low Flow appli-
cations (50-750 cc/min.)
4222
0.061 cc/pulse for Medium Flow
applications (500-1500 cc/min.)
0.150 cc/pulse for High Flow appli-
cations (1500-3800 cc/min.)
Pulse Width 0.50 ms 4223
Output Signal Passive - Positive 4226
Basic Function Process
Parameter
Configuration Assign Low
Flow Cut Off
Volume Flow 6400
On-Value Low
Flow Cut Off
30 cc/min for Medium and High
Flow applications (500-3800
cc/min.)
6402
5 cc/min for Low Flow applications
(50-1000 cc/min.)
+ –