User's Manual
Operation
20 313599P
HOME POSITION
Quick Setup
Mass Flow Volume Flow Density Temperature
Unit Mass Flow
Unit Volume
Flow
Unit Density
Unit
Temperature
QS Commission
Language
Current Span
Value 0/4
mA
Value 20
mA
Actual Settings
Operation
Mode
End Value
Freq.
Value F Low
Value F
High
Output
Signal
Assign Current
Output
Pulse
Width
Unit Totalizer
Time
Constant
Failsafe Mode
(see Note)
Delivery Settings
Measure
Mode
Pulse Value
Assign Freq.
Output
Assign Pulse
Output
PulseFrequency
Current Output n Freq./Pulse Output n Quit
Yes No
Unit Corr.
Vol. Flow
Corr. Vol. Flow
Corr. Vol.
Calculation
Selection pre-settings
Selection system units
Pre-setting
Reference Calculated
Unit Ref.
Density
Fix. Density
Exp.
Coeff. Lin
Exp.
Coeff.
Ref.
Temperature
Configure another system unit?
Selection output type
Configure another output?
Automatic configuration of display?
Automatic parameterization of
the display
Carrying out another quick setup?
Carrying out the selected quick setup
Pulsating flow Gas measurement
Quit
Unit Totalizer
Time
Constant
Output
Signal
Failsafe Mode
Failsafe Mode
Measure
Mode
Measure
Mode
Yes
Yes No
No
No
TI18909a
Cubemass Meter Function Matrix
NOTE: For certain filled materials, solids, or heavy
metallics, the meter will register flow but will not generate a
pulse output. For these specific applications, change
Parameter No. 4227 from Failsafe Mode to Actual Flow to
allow the meter to generate a pulse outlet.