User's Manual
Operation
313599P 19
Using Cubemass Meter with ProMix 2KS/2KE/3KS, Informer, or
ProControl 1KS/1KE System
Basic Installation Settings
The function matrix consists of groups which have a set
of related functions. See Cubemass Meter Function
Matrix on page 20.
To access groups and functions:
1. From HOME, press to enter the function matrix
and access the Block menu. See F
IG. 13.
2. Scroll through the Block menu. Press to save
the selection and advance to the Group menu.
3. Scroll through the Group menu. Press to save
the selection and advance to the Function Group
menu.
4. Scroll through the Function Group menu. Press
to save the selection and advance to the Function
menu.
NOTE: To enable meter programming, you need to
enter the access code. The factory setting is 84. See the
Endress+Hauser manual to change the access code.
5. Select a function. Press the or key to
change or enter parameters or numerical values.
See T
ABLE 3 on page 21. Press to save the
entries.
6. Press the and keys together to exit the
function matrix one level at a time. Press and hold
the and keys together for more than 3 sec
to return to the HOME position.
For additional Promass instructions, see the
Endress+Hauser manuals shipped with the meter, or
access the manuals online at www.endress.com.
IMPORTANT: Enter the correct K-factor (pulse value
function in T
ABLE 3 on page 21) and calibrate the meter
before operating.
E
E
E
E
+ –
E
+ –
+ –
FIG. 13: Cubemass Meter Group and Function Navigation
NOTE:
numbers represent steps of
Basic Installation Settings
procedure, page 19.