User's Manual

Operation
16 313599P
Using Promass Meter with ProMix 2KS/2KE/3KS or ProControl 1KS
System
Basic Installation Settings
The function matrix consists of groups which have a set
of related functions. See Promass Meter Function
Matrix on page 18.
To access groups and functions:
(Refer to FIG. 12.)
1. From HOME, press to enter function matrix and
access Group options.
2. To scroll from one Group to the next or previous
Group, press or .
3. To select the Group and access its Functions,
press .
4. To scroll through Functions, press .
5. To select a Function, press or .
NOTE: To enable meter programming, you need to
enter the access code. The factory setting is 80. See the
Endress+Hauser manual to change the access code.
6. To exit the function matrix one level at a time, press
and together.
NOTE: Pressing and holding and together for
more than 3 seconds will return you to HOME.
For additional Promass instructions, see the
Endress+Hauser manuals shipped with the meter, or
access the manuals online at www.endress.com.
IMPORTANT: Enter the correct K-factor (pulse value
function in T
ABLE 2 on page 17) and calibrate the meter
before operating the proportioner.
E
+
E
E
+
+
+
FIG. 12: Promass Meter Group and Function Navigation
HOME
ESC
–+
E
E
E E E E E
+
+
E
E
E
E
2
1
3 4
6
ESC
+
ESC
+
ESC
Hold 3 seconds
NOTE:
numbers represent steps of
Basic Installation Settings
procedure, page 16.
1