User's Manual
Installation
14 313599P
Informer and ProControl 1KE
Cable Connections.
Meter Power Cable
The meter is powered by a user-suppled 24V, 1 A, 24W.
power supply. Order Graco power supply 120369, if
desired.
Meter Signal Cable
Connect the meter signal cable to port 4 on your
Informer DCM or ProControl ADCM.
Cable Connections at Meter
The signal cable (9) is factory assembled to the meter.
The power cable is user provided.
See F
IG. 10. To service or replace components:
1. Remove meter cover and feed cable through hous-
ing. Connect signal cable (9) and wires (21, 22) per
wire schematic.
2. Install terminal (20) in the storage area of the meter.
3. Gently pull back extra signal cable and tighten cable
gland to secure cable.
To avoid electric shock, disconnect power source
before doing electrical wiring. All electrical wiring must
be done by a qualified electrician and comply with all
local codes and regulations.
FIG. 10. Power and Signal Connections at Meter,
Informer and ProControl 1KE
-27
+26
-25
+24
-23
+22
-21
+20
N (L-) 2
L1(L+) 1
9
METER
POWER
21
22
TERMINAL 1
20
TERMINAL 5
SHIELD (BARE OR BLACK) TO
TERMINAL (20) METER
124
225
SIGNAL CABLE (9) TERMINAL (20)
BROWN (POWER) 5
WHITE (SIGNAL) 4
GRAY (COMMON) 3
POWER CABLE METER
WHITE (L+) 1
BLACK (L-) 2
SHIELD/GROUND
FROM
SEPARATE
DC POWER
SUPPLY