User's Manual
Installation
313599P 13
Power and Signal Cable Connections
at Meter
The signal cable (4) is factory assembled to the meter.
The power cable (PC) is user-provided. If cables need
servicing or replacement, see F
IG. 9 and Table 1 to con-
nect to meter.
F
IG. 9. Power and Signal Connections at Meter,
ProMix 2KS/2KE/3KS and ProControl 1KS
-27
+26
-25
+24
-23
+22
-21
+20
N (L-) 2
L1(L+) 1
SIGNAL CABLE (4)
_______ WHITE (SIGNAL) _______ 24
_______ BLACK (COMMON) _______ 25
_______ SHIELD/GROUND _______
POWER CABLE (PC)
_______ WHITE (L+) _______ 1
_______ BLACK (L-) _______ 2
_______ SHIELD/GROUND _______
4
PC
FROM
SEPARATE
DC POWER
SUPPLY
Table 1: Signal Cable Connections
Meter
Proportioner
Wire Color
(Function)
Coriolis Meter
TerminalsProMix 2KE ProControl 1KS ProMix 2KS ProMix 3KS
Resin A Left-14 J3-3 J3-3 J3-3 White (Signal) 24
Left-13 J3-2 J3-2 J3-2 Black (Common) 25
Catalyst B Right-14
NA J3-6 J3-6 White (Signal) 24
Right-13 J3-5 J3-5 Black (Common) 25
Reducer C
NA NA NA J12-6 White (Signal) 24
J12-5 Black (Common) 25
Solvent
NA J12-3 J12-3 J12-3 White (Signal) 24
J12-2 J12-2 J12-2 Black (Common) 25
All Ground
Terminal Block
Ground
Terminal Block
Ground
Terminal Block
Ground
Terminal Block
Shield (Ground) Ground
Terminal Block