User's Manual
Repair
313540G 37
Primary Heaters
Heater Element
1. Turn main power OFF . Disconnect power
supply.
2. Relieve pressure, page 27.
3. Wait for heaters to cool.
4. Remove heater shroud.
5. See page 60 for parts. Disconnect heater element
wires from heater wire connector. Test with ohmme-
ter.
6. To remove heater element, first remove thermocou-
ple (410) to avoid damage, see step 7, page 38.
7. Remove heater element (407) from housing (401).
Be careful not to spill any fluid left in housing.
8. Inspect element. It should be relatively smooth and
shiny. If there is a crusted, burnt, ash-like material
adhered to element or sheath shows pitting marks,
replace element.
9. Install new heater element (407), holding mixer
(409) so it does not block thermocouple port (P).
10. Reinstall thermocouple, page 38.
11. Reconnect heater element leadwires to heater wire
connector.
12. Replace heater shroud.
Line Voltage
The primary heaters output their rated wattage at 230
Vac. Low line voltage will reduce power available and
the heaters will not perform at full capability.
Total Heater
Wattage Element Ohms
7,650 2550 18-21