User's Manual
Repair
34 313540G
Transducers
1. Turn main power OFF . Disconnect power
supply.
2. Relieve pressure, page 27.
3. Refer to electrical diagrams. Motor control board is
on right side inside cabinet.
4. Disconnect transducer cables at board; see F
IG. 6,
page 33. Reverse A and B connections and check if
diagnostic code follows; see E21: No component A
transducer, page 12.
5. If transducer fails test, thread cable through top of
cabinet. Note path as cable must be replaced in
same way.
6. Install o-ring (720) on new transducer (706), F
IG. 7.
7. Install transducer in manifold. Mark end of cable
with tape (red=transducer A, blue=transducer B).
8. Route cable into cabinet and thread into bundle as
before.
9. Connect transducer cable at board; see F
IG. 6, page
33.
Electric Fan
1. Turn main power OFF . Disconnect power
supply.
2. Relieve pressure, page 27.
3. Check fuses (F) at left of breaker module, F
IG. 8.
Replace if blown. If good, continue with step 4.
4. Refer to electrical diagrams. Disconnect fan wires
from fuses (F).
5. Remove fan.
6. Install fan in reverse order.
FIG. 7. Transducers
ti9885a
720
706 (B Side)
701
706 (A Side)
FIG. 8. Fan Fuses
F
ti9884a-1