User's Manual
Repair
30 313540G
Circuit Breaker Module
1. Turn main power OFF . Disconnect power
supply. Turn circuit breakers on to test.
2. Relieve pressure, page 27.
3. Using an ohmmeter, check for continuity across cir-
cuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to electrical diagrams and to T
ABLE 3. Dis-
connect wires and remove bad breaker.
b. Install new breaker and reconnect wires.
Table 3: Circuit Breakers, see FIG. 5
Ref. Size Component
809 50A Hose/Transformer
Secondary Side
811 40A Transformer
Primary
812A 50A Heater A
812B 50A Heater B
813 20A Motor/Pumps
FIG. 5. Circuit Breaker Module
ti9884a
812A
813
809
811
NOTE: To reference cables and con-
nectors, see the electrical diagrams and
the parts drawings on page 64.
812B