User's Manual

Installation and Setup
18 313292G
Installation and Setup
NOTE:
See , page 27, to aid in component installation.
Connect Air Lines
Refer to component identification in F
IG
. 1, page 9.
Refer to the pneumatic schematic drawings in the XM
Plural-Component Sprayer repair-parts manual 313289
for guidance.
Connect air lines (68, 69) between the fluid control
assembly (B) and the control box (C).
Connect air lines (68, 69) between the air controls
assembly (E) and the control box.
Connect Fluid Hoses
Use the following illustration as a guide to connect the
fluid hoses.
Connect Air Hoses
Connect air hose (12) between air inlet manifold and
air controls assembly. (Hose called out as 12(C)).
Connect air hose (12) between air controls assem-
bly and both air motors. (Hose called out has 12(A)
and 12 (B)).
Connect Sensor Cables
Connect pressure and temperature sensor cables (sup-
plied with fluid control assembly (B)) to the fluid control
module.
Recirculation
Hose (gray)
Hose to Pump
Lower (black)
Recirculation
Hose (gray)
12 (A and B)
12(C)
12(B)
12(A)
r_xmaa00_313292_4a
B
Fluid
Control
Module