User's Manual

Setup
312878J 21
Setup
Hydraulic Proportioner Setup
See hydraulic proportioner manual 312062.
Controller Setup
To enter the setup screens, press and hold the top soft
key for three seconds. To exit the setup screens, press
and hold both soft keys for three seconds. See F
IG. 2 on
page 8 for HMI button identification.
To navigate between the setup screens, for example
from setup screen #1 to setup screen #2, use the up
and down arrow keys. To navigate within a setup screen,
for example from the first page of setup screen #6 to the
second page of setup screen #6, use the soft keys.
See F
IG. 4 on page 12 for illustration of the setup
screens and navigation.
Setup Screen #1: System Data
This screen is a collection of system data that includes
the shot counter for each programmed shot, total piston
stroke counter, and a separate resettable piston stroke
counter. The piston stroke counters are displayed on the
last screen of setup screen #1.
To restart the counter for the resettable piston stroke
counter navigate to setup screen number one. Press the
top soft key to navigate to the next data page. Press the
top soft key repeatedly until the icon for the bottom soft
key is “0.” Press the bottom soft key to zero the counter
and confirm the selection when prompted.
Setup Screen #2: Shot Number Definitions
From setup screen #2, any of the twenty-five available
shot numbers can be edited. Each shot number can be
defined so that the machine will dispense the input
quantity of material when the shot number is selected
and a shot is initiated.
To edit a shot, navigate to setup screen #2. Press the
top soft key, and then use the arrow keys to highlight the
number of the shot to edit. Press the top soft key to
select and change the quantity for the selected shot
using the up and down arrow keys. Press the top soft
key to highlight the calibration factor. If required, use the
up and down arrow keys to adjust the calibration factor,
Refer to Calibration, page 30, for more information.
Press the top soft key to enter the change, and then
confirm the change when prompted.
Setup Screen #3: Shot Sequences
Setup screen #3 shows the five customizable shot
sequences, each with a sequence of ten shots. Each of
the ten shots in each sequence can be changed to any
of the shot numbers defined using setup screen #2. If
any sequence contains either an undefined shot or one
of the positions in the sequence is undefined, that shot
will be skipped when operating with that sequence.
When in any of the setup screens, pouring is dis-
abled.
The shot quantity units, cubic centimeters or grams,
for which each shot number quantity is defined is
dependent on whether the material specific gravity
has been entered. See Setup Screen #6: Quantity
Units and Gun Configuration on page 22.