User's Manual
Flow Control
312778D 27
Flow Control
The intrinsically safe flow regulator (FC) is required to
use flow control in your system.
1. Connect a 1/4 in. (6 mm) OD air supply line to the
air inlet fitting of the flow regulator (FC). Connect the
other end of this line as follows:
a. Wall Mount Systems: Connect to the air mani-
fold at the rear of the wall mount fluid station.
b. RoboMix Systems: Install a 1/4 in. (6 mm) OD
tube tee at the air logic inlet of the RoboMix.
Connect the flow control air line to one branch
of the tee and the main air line to the other
branch.
2. Connect a fluid inlet line from the static mixer tube at
the fluid station to the 1/8 npt(f) inlet of the flow reg-
ulator (FC).
3. Connect a fluid outlet line from the 1/8 npt(f) outlet
of the flow regulator (FC) to the spray gun inlet.
4. Connect the flow control cable to J5 on the fluid sta-
tion control board and to the cable connector on the
flow regulator (FC).
F
IG
. 16. Flow Control Regulator
TI13656a
FC
Fluid Outlet to Gun
Fluid Inlet from
Fluid Station
Air Line from
Fluid Station
Cable from
Fluid Station