User's Manual
Maintenance
12 312753E
Cleanout Plunger Proximity
Switch Replacement
The proximity switch on the cleanout plunger is a
high-pressure switch that extends directly into the
hydraulic fluid. The quick-disconnect feature on the
switch allows easy replacement of a failed or damaged
switch or cord set.
Tools Required
• 1 in. open-end wrench
Cord Set Replacement
1. Disconnect the cord set (BA) from the machine at
the Amphenol connector (BB).
2. Unscrew the knurled knob at the end of the cord
set (BA) and disconnect the cord set from the prox-
imity switch (BC) on the MixHead.
3. Match up the keys on the cord set (BA) with the key-
ways on the proximity switch (BC), insert the cord
set into the proximity switch, and tighten the knurled
knob.
4. Connect the cord set (BA) to the machine at the
Amphenol connector (BB).
• Do not operate the MixHead unless all proximity
switches are in place and the proximity switch
alarm is operational and armed.
• A shock hazard or unpredictable machine operation
could occur if the proximity switch is separated from
its mating cord set, or if either the proximity switch
or its mating cord set are used with a different
switch or cord set.
F
IG. 3
BA
BB
BD
BC
Key:
BA Proximity Switch Cord Set
BB Amphenol
®
Connector
BC Cleanout Plunger Proximity Switch
BD O-ring
See FIG. 3 on page 12.