User's Manual

Follower Plate Installation
2 312738C
Follower Plate Installation
Instructions
NOTE: Before the follower plate is installed in the drum
of grease, pack cone with grease.
1. Relieve pressure using the Pressure Relief Proce-
dure in your separate pump manual.
2. Remove pump.
3. Pack grease into follower plate cone (F
IG. 1).
4. Press follower plate, cone side up, into grease and
firmly press on it to remove all air pockets
NOTE: See Parts, page 5 and 6 for illustrations
showing cone side up position.
5. Push down on follower plate cylinder (6) until grease
starts to appear in pump opening at follower plate
grommet (11). See Parts, pages 5 and 6.
6. Reinstall pump and drum cover (See Drum Cover
Installation, page 3).
7. Prime pump.
FIG. 1
Pack Cone with Grease
Pack Cone with Grease
247701 and 77X511 247702 and 77X512
120# Reservoir Follower Plate 400# Reservoir Follower Plate