User's Manual
Miscellaneous Assemblies 
312393G    43 of 50 
Miscellaneous Mechanical Assemblies 
Figure 54: PR70 Power Entry Bracket Assembly (LC0106) 
Key: 
Ref P/N  Description  QTY   Ref P/N  Description  QTY
1  119912  SCREW, PAN, M3X6, PHILLIPS, SS  3 11 84/0130-26/11 LABEL, PE  1
2  121018  ELBOW, SWVL, 3/8 X ¼ NPT, FXM, 90DE 1 12 LC0034 HARNESS, WIRE, REMOTE SIGNAL 1
3  120876  PWR SUPPLY, 24VDC, 40W, 100-240VAC IN 1 13 121178 VALVE, LOCKOUT, ¼ NPT  1
4  120882  FILTER, 1/4NPT  1 14 121179 QUIKCLAMP, ¼ NPT  2
5  120883  NUT, HEX, 7/8-14, MS  1 15 121180 MULTIPORT, [3] ¼ NPT  1
6  120910  PWR ENTRY, 120/240VAC, DUAL FUSE, EMI  1 16 94/0762/99 VALVE, RELIEF, ¼ NPT, M, 110PSI, SIL 1
7  120916  SCREW,FHSC, M3X0.5 X 10, SS  2 17 94/0430/99 PLUG, SKT HD, ¼ NPT, MS  2
8  120993  NUT, HEX, M5X0.8, WITH STAR WASHER 2 18 81/1054-4/11 FUSE 5X20MM, 4AMP, FAST, TYPE F, 250VAC 2
9  15K798  BRACKET, SWITCH, AIR  1 19 LC0031 CABLE ASSY, POWER IN  1
10 15K800  FITTING, BULKHEAD  1
To Replace the Fuses: 
1.  Remove the machine fuse holder from the PWR 
Entry module (6) by inserting a flat-head 
screwdriver between the holder and the back the 
PWR Entry module (The fuse holder is above 
where AC power is connected to the machine). 
2.  Replace the blown fuse(s) (18) into the fuse holder. 
3.  Re-install the holder into the PWR Entry Module. 