User's Manual

Connection Kit 288202
311876F 7
Pump Performance Charts
NOTE: See pages 10-12 for E-Flo DC Performance
Charts.
Fluid Outlet Pressure
To find fluid outlet pressure (MPa/bar/psi) at a specific flow
(lpm/gpm) and operating pressure (A/B/C):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected operat-
ing pressure curve (solid line). Follow left to scale to read
fluid outlet pressure.
Air Consumption
To find air consumption (l/min. or gpm) at a specific fluid flow
(l/min. or gpm) and operating pressure (A/B/C):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air con-
sumption curve (gray line). Follow right to scale to read air
consumption.
Key
A 0.7 MPa, 7 bar (100 psi) air pressure
B 0.5 MPa, 4.9 bar (70 psi) air pressure
C 0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
NXT 2200 with 1000cc Lower
Fluid Pressure
A
B
psi (MPa, bar)
450 (3.1, 31)
400 (2.7, 27)
350 (2.4, 24)
300 (2.0, 20)
250 (1.7, 17)
200 (1.3, 13)
100 (0.68, 6.8)
0
Fluid Flow in gpm (lpm)
C
A
B
C
Air Flow (scfm)
20
30
40
50
60
70
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
150 (1.0, 10)
50 (0.34, 3.4)
10
cycles per minute
7142128354249