Pump Performance Charts
Fluid Outlet Pressure
To find fluid outlet pressure (MPa/bar/psi) at a specific flow
(lpm/gpm) and operating pressure (A/B/C):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected operat-
ing pressure curve (solid line). Follow left to scale to read
fluid outlet pressure.
Air Consumption
To find air consumption (l/min. or gpm) at a specific fluid flow
(l/min. or gpm) and operating pressure (A/B/C):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air con-
sumption curve (dashed line). Follow left to scale to read
air consumption.
Key
A 0.7 MPa, 7 bar (100 psi) air pressure
B 0.5 MPa, 4.9 bar (70 psi) air pressure
C 0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
President with 750cc Lower
500
(3.5, 35)
A
B
A
B
C
Fluid Pressure
psi (MPa, bar)
300
(2.0, 20)
200
(1.3, 13)
100
(0.69, 6.9)
Air Consumption
40
(1.12)
C
0
30
(0.84)
20
(0.56)
10
(0.28)
scfm
(m
3
/min)
50
(1.40)
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
Fluid Flow in gpm (lpm)
02.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
Fluid Flow in gpm (lpm)
400
(2.7, 27)
cycles per minute
12 25 37 50 62
cycles per minute
12 25 37 50 62