User's Manual
Connection Kit 24F308
311876F 21
Pump Performance Charts
Fluid Outlet Pressure
To find fluid outlet pressure (MPa/bar/psi) at a specific flow
(lpm/gpm) and operating pressure (A/B/C):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected operat-
ing pressure curve (solid line). Follow left to scale to read
fluid outlet pressure.
Air Consumption
To find air consumption (l/min. or gpm) at a specific fluid flow
(l/min. or gpm) and operating pressure (A/B/C):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air con-
sumption curve (gray line). Follow right to scale to read air
consumption.
Key
A 0.7 MPa, 7 bar (100 psi) air pressure
B 0.5 MPa, 4.9 bar (70 psi) air pressure
C 0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
Senator with 1000cc Lower
A
B
C
A
B
C
Fluid Pressure
psi (MPa, bar)
350 (2.4, 24)
300 (2.0, 20)
250 (1.7, 17)
200 (1.3, 13)
150 (1.0, 10
100 (0.69, 6.9)
50 (0.34, 3.4)
0
Fluid Flow in gpm (lpm)
Air Flow (scfm)
10
30
40
50
20
60
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
cycles per minute
7142128354249