User's Manual

Connection Kit 288504
18 311876F
Pump Performance Charts
Fluid Outlet Pressure
To find fluid outlet pressure (MPa/bar/psi) at a specific flow
(lpm/gpm) and operating pressure (A/B/C/D):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected operat-
ing pressure curve (solid line). Follow left to scale to read
fluid outlet pressure.
Air Consumption
To find air consumption (l/min. or gpm) at a specific fluid flow
(l/min. or gpm) and operating pressure (A/B/C/D):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air con-
sumption curve (gray line). Follow right to scale to read air
consumption.
Key
A 1.17 MPa, 11.7 bar (170 psi) air pressure
B 0.7 MPa, 7 bar (100 psi) air pressure
C 0.5 MPa, 4.9 bar (70 psi) air pressure
D 0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
President with 1000cc Lower
A
B
C
A
B
C
Fluid Pressure
psi (MPa, bar)
350 (2.4, 24)
300 (2.0, 20)
250 (1.7, 17)
200 (1.3, 13)
150 (1.0, 10)
100 (0.69, 6.9)
50 (0.34, 3.4)
0
Fluid Flow in gpm (lpm)
Air Flow (scfm)
10
30
40
50
20
60
400 (2.7, 27)
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
D
D
cycles per minute
8 172533425159