Pump Performance Charts
NOTE: See pages 7-8 for NXT 2200 and NXT 3400 Per-
formance Charts.
Fluid Outlet Pressure
To find fluid outlet pressure (psi/MPa/bar) at a specific flow
(gpm/lpm) and percentage of maximum force (A/B/C):
1. Locate desired flow at bottom of chart.
2. Follow vertical line up to intersection with selected per-
centage of maximum force (see the Key below).
3. Follow left to vertical scale to read fluid outlet pressure.
Key to E-Flo DC Performance Charts
NOTE: The charts show the motor operating at 100%, 70%,
and 40% of maximum force. These values are approximately
equivalent to an air motor operating at 100, 70, and 40 psi..
A 100% of maximum force
B 70% of maximum force
C 40% of maximum force
Test Fluid: No. 10 Weight Oil
1 HP Motor (1400 lb maximum force) with 750cc Lower
Fluid Pressure
A
B
psi (MPa, bar)
Fluid Flow in gpm (lpm)
C
cycles per minute