User's Manual
Repair
311833D 13
Reconnect the Lower
1. Screw the connecting rod adapter (5) to the air
motor shaft. Torque as noted in F
IG
. 3.
2. Screw the tie rods (6) into the air motor (1). Using a
wrench on the tie rod flats, torque as noted.
3. Make sure the coupling nut (3) and coupling collars
(4) are in place on the displacement rod.
4. Use at least two people to hold the lower while
another reconnects it to the motor (see the CAU-
TION, page 12). Orient the pump's fluid outlet to the
air inlet as noted under Disconnect the Lower.
Place the lower (2) on the tie rods (6).
5. Screw the nuts (7) onto the tie rods (6) and torque
as noted in F
IG
. 3.
6. Screw the coupling nut (3) onto the connecting rod
adapter (5) loosely. Hold the connecting rod adapter
flats with a wrench to keep it from turning. Use an
adjustable wrench to tighten the coupling nut.
Torque as noted in F
IG
. 3.
7. Reconnect all hoses. Reconnect the ground wire if it
was disconnected. Fill the wet-cup 1/3 full of Graco
Throat Seal Liquid or compatible solvent.
8. Turn on the air power supply. Run the pump slowly
to ensure that it operates properly.
F
IG
. 3. Reconnect the Lower
TI8363a
1
3
6
2
7
5
1
1
Torque to 196-210 N•m (145-155 ft-lb)
1