User's Manual

Flushing
311075U 29
Flushing
Generally, flush if you will be shut down for
more than 3 days. Flush more often if
material is moisture sensitive and humidity
is high in the storage area, or if material
may separate or settle out over time.
Flush out old fluid with new fluid, or flush
out old fluid with a compatible solvent
before introducing new fluid.
Use the lowest possible pressure when
flushing.
Always leave some type of fluid in system.
Do not use water.
For long term storage, flush out the solvent
with a storage fluid such as Bayer Mesa-
moll plasticizer or, at minimum, clean motor
oil.
Flush equipment only in a well-ventilated
area. Do not spray flammable fluids. Do not
turn on heaters while flushing with flammable
solvents.
1.
Engage piston safety lock or trigger
safety lock. Close fluid valves A and B.
Leave air on.
Fusion
MD2
ti10442a
2.
Set function knob to Stop/Park .
3.
Shut off Heater Power (heated units
only). Allow system to cool.
4.
Remove recirculation tubes (31) from
supply tanks and place in original con-
tainers or waste containers.
5.
Turn Recirc/Spray valves to Recirc.
6.
Set function knob to Fast Recirc .
Pump material from supply tanks until
no more comes out.
TI7022a
31