Instructions Parts Piston Fluid Flow Meter 309148B 3000 psi (21 MPa, 210 bar) Maximum Working Fluid Pressure Part No. 116161 .01 to 2.6 gpm (40 to 10,000 cc/min.) Flow Range Intrinsically Safe for Hazardous Locations (Class I; Division 1; Group D) when used with an approved barrier only. Read warnings and instructions. TI0258 GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 2001, Graco Inc. is registered to I.S.
Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Meter Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 4 5 6 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Grace Standard Warranty . . . . . . . . . . . . . . . . . . . . . .
WARNING INJECTION HAZARD Spray from leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause serious injury. Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention. Do not stop or deflect fluid leaks with your hand, body, glove, or rag.
Installation WARNING FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD To reduce the risk of fire, explosion, or electric shock: All electrical equipment must only be installed by a qualified electrician. Understand and follow your local code and safety regulations for hazardous location wiring of intrinsically safe circuits.
Operation Pressure Relief Procedure WARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: are instructed to relieve the pressure, stop spraying, check or service any of the system equipment. 1.
Parts Use Only Genuine Graco Parts and Accessories Part No. 243513 Piston Meter Kit, for solvent-borne materials (0.8–20 cps) Ref. No. 1* 1a* 1b* 1c* Part No. Description 116161 METER, piston; for solventborne materials only; includes replaceable items 1a–1d TRANSMITTER, sensor METER, piston type KIT, repair, o–ring; includes 4 PTFE end cap o–rings, 2 PTFE base o–rings, and 1 Viton transmitter o–ring.
Technical Data Category Data Category Data Maximum Working Fluid Pressure 3000 psi (21 MPa, 210 bar) Supply Voltage 4.5–15 Vdc Intrinsic Safety Flow Range 0.01–2.6 gal/min (40–10,000 cc/min) Class 1; Div. 1; Group D V max.= 15 V I max. = 15 mA Ci = 0.2 mf Li = 0mH Approvals See front cover Wetted Parts 303 and 440C Stainless Steel, PTFE Fluid Temperature Range 40–180 F (4–80 C) Maximum Ambient Temperature 180 F (80 C) Fluid Viscosity Range 0.
Grace Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.