User's Manual

308968 9
Troubleshooting
NOTE: The sensor is not a serviceable part. Replace it
if it is malfunctioning.
Problem Cause Solution
No flow volume displayed at mon-
itoring unit
Flow volume is too low to measure Increase flow volume.
Fluid is not flowing See Problem: Fluid is not flowing,
below.
Damaged cable Replace cable.
Improper input voltage to sensor Make sure input power is 729 Vdc.
Damaged sensor Replace sensor if it is malfunctioning.
Fluid is not flowing Clogs in fluid line or in meter Clean fluid line and/or meter; see
Maintenance section.
Gears worn or damaged Service meter; see Maintenance
section.