User's Manual
6 308968
Installation
WARNING
FIRE, EXPLOSION, AND ELECTRIC
SHOCK HAZARD
To reduce the risk of fire, explosion, or
electric shock:
D All electrical equipment must only be installed
by a qualified electrician.
D Understand and follow your local code and
safety regulations for hazardous location wiring
of intrinsically safe circuits.
Dust and Foreign Matter
Avoid having dust or foreign matter enter the flow
meter by taking the following precautions:
D Thoroughly flush the fluid supply lines before
installing the flow meter.
D When installing fittings, make sure that no sealing
tape overlaps into the inside of the pipe.
CAUTION
The use of PTFE tape or pipe seal on fluid fittings
upstream of this meter should be avoided if possible.
Contaminants from sealing material may damage
the meter.
D Install a 100 mesh fluid filter upstream of the flow
meter.
Installing the Flow Meter
D Flow volume can only be measured at the location
where the flow meter is installed.
D Do not use more than 200 ft. (61 m) of cable.
D Refer to Fig. NO TAG to locate and install the flow
meter, connectors, and fluid shutoff valves. Install a
check valve upstream of the meter to prevent
backflow. The arrows on the flow meter and check
valve show the direction of fluid flow.
D The shutoff valves allow you to isolate the meter for
service.
D Refer to the Technical Data and Dimensional
Drawings for dimension, inlet/outlet size, tempera-
ture and other specifications.
Fig. 1
Flow Meter
Fluid Shutoff Valve
on inlet side
Fluid Shutoff Valve
on outlet side
Fluid Line
Check Valve
TI1003