User's Manual

308-859 7
Technical
Data
Category Data
Maximum
air input pressure
300 psi (2.1 MPa, 21 bar)
Air pressure range
5 to 150 psi (.03 to 1 MPa, 0.3 to 10 bar)
Air inlet and outlet size
Part No. 1
14–459:
1 in. npt(f)
Part No. 1
14–105:
1/2 npt(f)
Gauge port size (air regulator)
1/4 npt(f)
Maximum operating temperature
175_F (79_C)
0
20
40
60
80
100
0 40 80 120 160 200
scfm
m
#/
min
1.120 4.480 5.600
PRESSURE DROP
MODEL
1
14–105 AIR REGULA
T
OR FLOW CUR
VE
psi
bar
MPa
7.0
0.7
5.6
0.56
4.2
0.42
2.8
0.28
1.4
0.14
AIR FLOW A
T INLET PRESSURE OF 100 PSI (0.7 MPa, 7 BAR)
2.240 3.360
0
40
80
120
0 80 160 240 320 400 480
scfm
m
#/
min
4.480 6.720
PRESSURE DROP
MODEL 1
14–459 AIR REGULA
T
OR FLOW CUR
VE
psi
bar
MPa
8.4
0.84
5.6
0.56
2.8
0.28
AIR FLOW A
T INLET PRESSURE OF 150 PSI (0.84 MPa, 8.4 BAR)
2.240 8.920 11.200 13.440