INSTRUCTIONS-PARTS LIST This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308–807 Rev. B Supersedes A First choice when quality counts.t INSTRUCTIONS Ultra-Litet In-Line Flow Gun 3400 psi (23.4 MPa, 234 bar) Maximum Working Pressure Model 240–199 With Ball End Needle Model 240–200 With Tapered Needle 7903A GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN Graco Inc. is registered to I.S.
Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Technical Data . . . . . . . . . . . . . . . . . . . .
WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories. D Check equipment daily.
Installation Grounding WARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 3. 1. Pump: use a ground wire and clamp as shown in your separate pump manual. 2. Fluid hoses: use only electrically conductive fluid hoses with a maximum of 500 feet (150 m) combined hose length to ensure grounding continuity. Check the electrical resistance of your fluid hoses at least once a week.
Operation Pressure Relief Procedure Flow Rate Adjustment WARNING WARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or dispensing accidentally. Fluid under high pressure can be injected through the skin and cause serious injury.
Service NOTE: Repair kits are available. See page 7 for the kits for your gun model. For the best results, use all the new parts in the kit. Kit parts are marked with an asterisk, for example (2*). NOTE: See the Parts Drawing on page 7 when disassembling and reassembling the gun. Disassembly WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5. Reassembly 1. Apply grease to the needle (2*) o-rings. 2.
Parts 11 5 3 2 1 2 12 6 10 1 A 1 Grease the needle o-rings. 2 Torque to 18–22 in-lb (2.03–2.46 NSm). B 7904A Models 240–199 and 240–200 Ref No. 1 2* Part No.
Technical Data Category Data Maximum working pressure 3400 psi (23.4 MPa, 234 bar) Maximum temperature 120_ F (49_ C) Flow rate at 2000 psi (14 MPa, 138 bar)* Model 240–199: 158 oz/min (4.5 kg/min) Model 240–200: 154 oz/min (4.4 kg/min) Outlet port size 1/4 npt(f) and flange Inlet port size 1/4 npt(f) Dry weight Model 240–199: 11.6 oz (325 gm) Model 240–200: 11.6 oz (325 gm) Length 5.9 in (15.0 cm) Width 2.6 in (6.6 cm) Thickness 0.85 in (2.
Notes 308-807 9
Notes 10 308-807
Notes 308-807 11
Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
3X8–807 Rev. C Supersedes Rev. B Parts Change Notice Some parts in Rev. B of manual 308–807 have changed but have not yet been changed in the instruction manual. Please note the changes below and mark them in your manual or keep this sheet with your manual. Assembly No. Series Letter Change Part That Changed Ref No. Part Description Description of Change B 114–330 3 Trigger Replaced by Part No.