User's Manual
9308797
Installation
Changing the Orientation of the Fluid Inlet
and Outlet Ports
Fig. 4. You can change the orientation of the fluid inlet
and outlet ports by repositioning the manifolds.
1.
Relieve the pressure. See Pres-
sure Relief Procedure on page 10.
2. Remove four manifold bolts (105).
3. Turn manifold to desired position, reinstall bolts,
and torque to 80 to 90 in-lb (9 to 10 Nm). See
Torque Sequence, page 20.
NOTE: Make sure all manifold o-rings are posi-
tioned correctly before you fasten the manifold.
Manifold o-rings (139) are shown in Fig. 6.
Fig. 4
1
Torque to 80 to 90 in-lb (9 to 10 Nm). See
Torque Sequence, page 20.
1
105
9071A
outlet
inlet
1
105