User's Manual

5308-674
Installation
General Information
NOTE:
Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE:
Always use Genuine Graco Parts and Acces
-
sories, available from your Graco distributor
.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below
. Also read
the section
FIRE OR EXPLOSION HAZ
-
ARD
on page 4.
1.
Pump:
use a system ground wire and clamp. See
manual 308–61
1.
2.
Hydraulic, and fluid hoses:
use only electrically
conductive hoses.
3.
Hydraulic power supply:
follow manufacturer
’s
recommendations.
4.
Spray gun:
ground through connection to a prop
-
erly grounded fluid hose and pump.
5.
Fluid supply container:
follow your local code.
6.
Object being sprayed:
follow your local code.
7.
Solvent pails used when flushing:
follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu
-
ity.
8.
T
o maintain grounding continuity when flushing or
relieving pressure
, hold a metal part of the spray
gun firmly to the side of a grounded
metal
pail,
then trigger the gun.