Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below
. Also read
the section
FIRE OR EXPLOSION HAZ
-
ARD
on page 4.
Pump:
Use a ground wire and clamp. See
separate system manual.
Hydraulic, and fluid hoses:
Use only electrically
conductive hoses.
Hydraulic power supply:
Follow manufacturer
’s
recommendations.
Spray gun:
Ground through connection to a
properly grounded fluid hose and pump.
Fluid supply container:
Follow your local code.
Object being sprayed:
Follow your local code.
Solvent pails used when flushing:
Follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the pail
on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding
continuity.
T
o maintain grounding continuity when flushing or
relieving pressure
, hold a metal part of the spray
gun firmly to the side of a grounded
metal
pail, then
trigger the gun.