User's Manual
308345 9
Operation
1. Turn on the air supply to start the mixer. Regulate
the helix speed with the needle valve (18).
2. Operate the mixer continuously when supplying
paints or other fluids to the system.
8
4
7
Fig. 6
18
F
Model 236629 shown
03400B
Shutting Down
1. To stop the mixer, close the needle valve (18), or
disconnect the quick-disconnect (F), or close the
air valve in the air supply line.
2. If you remove the mixer from the drum, remove
the bearing nut (8), and hang or tilt the mixer
upright over a container to allow it to drain. Acces-
sory handle Part No. 189658 is available so you
can connect a lift hook to raise and lower the mixer
or hang the mixer to store it.
CAUTION
Keep the mixer upright. Do not lay it on its side or
upside down, because fluid might flow into the belt-
drive area.
If you use the accessory mixer handle, make sure
the mixer is loosened from the drum before you raise
it with a lift. The handle will not support the weight of
the drum.
Do not let fluid from dry in the fluid tubes. See Clean-
ing the Fluid Tubes on page 10.