User's Manual
3082256
Model Charts
Pressure and Ratio Ratings for Bulldog Pumps
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of over-pressurizing a component, which can result in an explosion and serious injury, never
operate the system at a working pressure higher than the lowest rated component in the system. All fluid side
components, such as dispensing valves; regulators; and hoses, must have a working pressure equal to or
greater than the pressure given in Column B for each pump model.
Column A gives the maximum pump fluid output pressure.
Column B gives the minimum working pressure required for all system components, based on the automatic relief
valve settings. Components included by Graco with the models listed meet or exceed this requirement.
Models with Two Displacement Pumps
A B
Mix
Model No.
Maximum Pump
Fluid Output
Pressure*
At Maximum
Air Pressure
Of:
Minimum
Component
Working Pressure
Normal
Pressure
Ratio
(Fl id t Ai )
Nominal
Flow
Volume
@ 40 cpm
Mix
Ratio
Bare Wall Stand psi
MPa, bar
psi MPa, bar psi
MPA, bar
(Fluid to Air)
gpm lpm
1:1 231897 231836 231865 3000 21, 207 86 0.6, 6 3000 21, 207 34.7 1.8 6.8
Models with Three Displacement Pumps
A B
Mix
Model No.
Maximum Pump
Fluid Output
Pressure*
At Maximum
Air Pressure
Of
Minimum
Component
Working Pressure
Normal
Pressure
Ratio
(Fl id t Ai )
Nominal
Flow
Volume
@ 40 cpm
Mi
x
Ratio
Bare Wall Stand psi
MPA, bar
psi MPa, bar psi
MPA, bar
(Fluid to Air)
gpm lpm
2:1 231908 231847 231876 2320 16, 160 100 0.7, 7 2900 20, 200 23.2 2.7 10.1
2:1 231910 231849 231878 3000 21, 207 86 0.6, 6 3600 25, 248 34.7 1.8 6.7
3:1 231912 231851 231880 2610 18, 180 100 0.7, 7 2900 20, 200 26.1 2.4 8.9
4:1 231915 231854 231883 2780 19, 192 100 0.7, 7 2900 20, 200 27.8 2.2 8.4