Spraying
20 3A9014C
Cup Refills
1. Turn Prime Knob down to PRIME
position to relieve system pressure.
2. Remove cup assembly from sprayer.
Remove the Pump Filter and clean
debris from the filter screen.
3. Reinstall the Pump Filter into the pump.
Set sprayer on a rag.
4. Refill the cup following Cup Fill, page
11, steps 3 and 4. Then follow Startup,
page 14, instructions to proceed.
Pause in Spraying
Paint will dry quickly and cause clogs in the
sprayer. Follow these steps whenever you
pause spraying for 5 minutes to 2 hours.
1. Turn Prime Knob down to PRIME
position to relieve system pressure.
2. Unplug Power Cord.
3. Turn Spray Tip 90 degrees to seal orifice
from drying out.
4. Ensure sprayer is fully sealed. Ensure
VacuValve is closed and cup is attached
to sprayer with all air evacuated.