Full Product Manual

Setup
3A8110D 9
Setup
Configuration
The PowerFill is capable of being set-up with
the outlet on the left or right, depending on
user preference.
To change orientation, proceed with the
following steps.
ProConnect Cover Orientation
The ProConnect cover holds the pump in
place and is a guard for the pump rod. To
ensure Power Head is easy to remove and
install, the ProConnect cover needs to swing
away from outlet tube. To change the
orientation of the ProConnect cover, follow
the steps below.
1. Remove battery, see Battery
Installation and Removal, page 15.
2. Disconnect Power Head from pump, if
necessary. See Power Head Removal,
page 25.
3. Using a 1/4 in. nut driver, remove the
locking screw. Remove thumb screw.
Using a 1/2 in. (or 13 mm) wrench,
remove flanged bolt and spacer.
4. Flip ProConnect cover to rotate opposite
way. Re-assemble flange bolt with
spacer, locking screw, and thumb screw
to secure.