Full Product Manual

Troubleshooting
3A8110D 31
To Test Functionality - Standard Series
1. Using an Ohm meter, probe the ribbon
lines 2 and 3 and press the dispense
button. It should read ~0 ohms (Photo
A).
2. If Ohm meter does not read ~0 ohms
when pressing the dispense button,
replace the switch.
To Test Functionality - Pro Series
1. Using an Ohm meter, probe the ribbon
lines 2 and 3 and press the dispense
button. It should read ~0 ohms (Photo
B).
2. Probe ribbon lines 1 and 4 and press the
Repeat button. It should read OL or
MOhms (Photo C).
3. Probe ribbon lines 1 and 5 and press the
Repeat button. It should read OL or
MOhms (Photo D).
4. Probe ribbon lines 4 and 5 and press the
Repeat button. It should read ~0 ohms
(Photo E).
5. If Ohm meter does not read these
values, replace switch assembly.