Start Up
3A9019C EN 15
Start Up
Pressure Relief Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
1. Engage the trigger lock. Always engage
the trigger lock when sprayer is stopped
to prevent the gun from being triggered
accidentally.
2. Turn ON/OFF switch to the OFF
position. Button is not illuminated when
OFF.
3. Turn pressure control knob to lowest setting.
4. Put Drain Tube into a waste pail and turn
Prime/Spray Valve down to PRIME position
to relieve pressure.
5. Hold the gun firmly to a pail. Point gun into
pail. Disengage the trigger lock and trigger
the gun to relieve pressure.
6. Engage the trigger lock.
7. If you suspect that pressure has not been
fully relieved, see Blockages, page 19.
NOTE: Leave Prime/Spray Valve in the PRIME
position until you are ready to spray.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection or splashed
fluid, follow the Pressure Relief
Procedure whenever sprayer is stopped
and before sprayer is cleaned or checked,
and before equipment is serviced.