SDS

Safety Data Sheet
Graco Pump Armor
Revision Date:
1/20/15
SDS Number:
MSD029EN
Section 313 toxic chemicals:
CERCLA:
State Regulations
Right-to-know
Other:
SECTION 16
HEALTH:
FIRE:
REACTIVITY:
SPECIFIC HAZARD:
PROTECTION INDEX:
Version:
Revisions / Comments:
Ethylene Glycol (Florida, Massachusetts, Minnesota, Pennsylvania), Diethylene Glycol in trace
amounts (Minnesota, Pennsylvannia).
Clean Air Act of 1990: Spills of one pound (~1 pint) or more must be reported.
For location specific information contact the EPA's Chemical Emergency
Preparedness Program Hotline (800-535-0202).
EPA Toxin: This material is an EPA toxin (ethylene glycol).
Recommend contacting the local authorities in the event of any type of spill to determine local
reporting requirements and also to aid in the cleanup.
Ethylene glycol <60%
NFPA 704
Fire (hazard):
NPCA-HMIS KEY
OTHER INFORMATION
Chronic (delayed health effects):
Reactivity (hazard):
Pressure ( sudden release hazard):
For stationary sources – reportable quantity:
5000 pounds due to ethylene glycol.
For moving sources – reportable quantity:
5000 pounds due to ethylene glycol.
VI
Re-evaluated GHS classification and updated sections 2 and 3: 10/30/2013
Updated Sections 14 and 15, reviewed entire document: 9/11/2014
Re-evaluated Section 2 based on reation products present in the final material, revised Section 3
based on reaction products present in the final material, revised Section 4 per customer request,
revised Section 5, revised Section 9, added information to "Other" field of Section 11 per
customer request, added information to "Other" field of Section 14 per customer request, upated
Section 16: 9/19/2014
Added customer part numbers, updated SDS number, added email address to contact
information, updated footer of last page per customer request: 9/23/2014
Added missing CAS number to Section 3: 9/26/2014
Added marine pollutant statement per customer request: 10/10/2014
Updated Section 14: 1/20/2015
0 = Minimal
1 = Slight
2 = Moderate
3 = Serious
4 = Severe
2
1
0
None
N/A B
N/A
0
1
2
NO
NO
NO
NO
This Safety Data Sheet and the information it contains is offered to you in good faith as accurate. We have reviewed any information contained in
this Data Sheet which we have received from sources outside our company. We believe that information to be correct, but cannot guarantee its
accuracy or completeness. Health and safety precautions in this Data Sheet may not be adequate for all individuals and/or situations. It is the
users' obligation to evaluate and use this product safely and to comply with all applicable laws and regulations. No statement made in this Data
Sheet shall be construed as a permission or recommendation for the use of any product in a manner that might infringe existing patents. No
warranty is made, either express or implied.
NOTES: NA = Not Applicable; NE = Not Established; UN = Unavailable
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Headquarters: Minneapolis
International Offices: Belgium, Korea, Hong Kong, Japan
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441