User Manual
Service
308244C 3
Service
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1. Engage trigger lock.
2. Turn ON/OFF switch to OFF.
3. Disengage trigger lock. Hold metal part of gun
against grounded metal pail and trigger gun into pail
to relieve pressure.
4. Engage the trigger lock.
5. Open all fluid drain valves in the system, having a
waste container ready to catch drainage. Leave drain
valve(s) open until you are ready to spray again.
6. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved:
a. VERY SLOWLY loosen tip guard retaining nut
or the hose end coupling to relieve pressure
gradually.
b. Loosen the nut or the coupling completely.
c. Clear the obstruction in the hose or tip.
Installation
1. Install the adapter on the gun as shown, but do not
install a spray tip yet. Be sure the gaskets are in
place.
2. Flush and prime the spray system.
3. Relieve the pressure.
4. Install the spray tip.
5. Turn the adapter to any desired position with 180°.
Do not use any tools.
6. Refer to your separate gun instruction manual for
operating and tip cleaning instructions.
7. This adapter is not repairable.
Technical Data
Maximum Working Pressure............................3600 psi
(24.8 MPa, 248 bar)
Fluid Inlet/Outlet Size...................................7/8-14 UNC
Wetted Parts............................Aluminum, acetal, PTFE,
Nylon, Stainless Steel
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection, splash-
ing fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before clean-
ing, checking, or servicing the equipment.
To reduce the risk of serious bodily injury from fluid
injection or splashing in the eyes or on the skin, stop
using the nozzle immediately if it starts to leak or
cannot be turned easily.
NOTICE
To avoid damage to the o-ring in the swivel, relieve
fluid pressure before rotating the swivel. Do not soak
the entire swivel in solvent.
180˚
ti26836a
180˚
Standard Flat Tip Guard
RAC DripLess Tip Guard