Replacement Part List
Table Of Contents
3A5572B EN 13
Assembly Verification
After assembly is complete, perform the
following steps to verify proper operation. If
sprayer fails one of the steps, repeat sprayer
repair procedures.
1. Visually inspect for gaps between
enclosure halves. A gap larger than 1/32
in. (0.8 mm) may be caused by a pinched
wire or an internal component not seated
properly. If disassembly and inspection
indicates that no wire has been pinched
and all internal components are seated
properly, carefully reassemble and
repeat verification steps.
2. Lift and lower Prime/Spray Valve to
make sure the valve lifts up to the PRIME
position and lowers down to the SPRAY
position.
3. Turn pressure control knob to verify it
rotates.
4. Using water, verify sprayer primes and
sprays. Follow instructions in your
sprayer Owners Manual for proper
setup, priming and spraying procedures.