Replacement Part List
Table Of Contents
10 3A5572B EN
Prime/Spray Valve and
Handle Replacement
1. Unplug power cord (22) and perform
Pressure Relief Procedure, page 1.
2. Lower Prime/Spray Valve to SPRAY
position.
3. Remove pin (33b) with pin punch and
hammer.
4. Remove Prime/Spray Valve handle
(33a).
5. Remove valve stem assembly (33) from
pump housing (1). Be sure gasket (C)
and seat (D) do not stay in pump housing
(1).
6. Apply sealant to threads of new valve
stem assembly (33). Install valve
assembly in pump housing. Torque to
220-250 in-lb (24.9-28.2 N•m).
7. Insert end of pin punch through hole in
Prime/Spray Valve handle and valve
stem to align.
8. Install pin (33b) through aligned holes.
Tap pin through with hammer. End of pin
will be flush with top of hole in
Prime/Spray Valve handle when
correctly installed.
9. After assembly is complete, perform
Assembly Verification, page 13.