Instructions / Assembly
Storage 
24 3A3208B
3. Turn Prime/Spray valve down to 
PRIME position.
4. Turn ON/OFF switch to ON position.
5. Turn pressure control knob clockwise 
until the pump turns on.
6. When storage fluid comes out of drain 
tube (5-10 seconds) turn ON/OFF 
switch to OFF position.
7. Turn Prime/Spray valve horizontal to 
SPRAY position to keep storage fluid in 
sprayer during storage.
8. Leave gun attached to hose.
9. Remove tip and guard and clean with 
water or flushing fluid and a brush.
10. Wipe paint off outside of gun using a 
soft cloth moistened with water or flush-
ing fluid.
11. Secure a plastic bag around suction 
and drain tube to catch any drips.
ti27120a
ti27121a
ti27190a










